Reduced Dewpoint System
(Air Quality to ISO 8573.1: Class 1.4.1)
Where dewpoint is not required to be less than 3-10°C.
Extremely Low Dewpoint System (Air Quality to ISO 8573.1: Class 1.1.1 and 1.2.1)
Where totally dry compressed air is required dewpoint between -40°C and -70°C. To stop corrosion from compressed air at 20°C and 7 bar g. A -30°C DP is the minimum requirement.
Terminal Filtration
*Where no main line filters are fitted or where the length of the pipe from the main filters is excessive. Grade AO pre-filters should be installed before the filters shown.
• Spray painting booths • Breathing air • Advanced pneumatics • Instrumentation • Blow guns • Measuring equipment • Gauging equipment • Hand tools
Installation Hints
1. Generally install filters downstream of aftercoolers and air receivers at the lowest installation temperature and as close to the point of application as possible This ensures that in wet systems as much water and oil vapour has condensed out as possible which can be removed by the coalescing filters. Installing close to the application reduces the risk of pipe scale downstream or the filters contaminating the filtered air. Please refer to above installation hints.
2. Filters should not be installed downstream of quick opening valves and should be protected from possible reverse flow or other shock conditions.
3. It may he necessary to install a combination of main line filtration near the compressor installation before entry to the ring main and install terminal filtration at the critical points. Remember especially in existing installations the contamination already in the pipe system downstream of the filters will take a long time to disappear and probably never will completely.
4. Purge all lines leading to the filters before installation and connection to the final application to be protected
5. Install filters in a vertical position ensuring that there is sufficient room below the filters to facilitate element change.
6. Avoid by-pass lines whenever possible as contamination may leak through valves and by-pass the filters.
7. Provide a facility to drain away collected liquids where applicable from the filter drains via suitable tubing taking care that no restrictions are caused.
8. Install domnick hunter differential pressure gauges and kits to indicate the pressure drop across the filters. This will give an idea of the filter element condition (except Grade AC or ACS).
9. domnick hunter mounting kits are available for filter sizes up to 0620G. Care should be taken with larger filters to see that they are properly supported in the pipe line.
10. If you have a problem on filter selection or installation please contact the domnick hunter Technical Sales Department or our representatives We will be pleased to help you in selecting the installation for your requirements.
|